RADIOELECTRIC EMISSIONS LEGISLATION SPAIN ROYAL DECREE ROYAL DECREE RD 1066/2001

Royal Decree RD 1066/2001 approves the Regulation that establishes conditions for the protection of the public radioelectric domain, restrictions on radioelectric emissions and health protection measures against radioelectric emissions. This decree is based on the European directive and establishes maximum levels for electromagnetic fields, as well as a protocol for their measurement.

Content of Royal Decree RD 1066/2001

The full contents of the RD can be consulted at this link:

Download here:

Royal Decree 1066/2011

It establishes:

  • Maximum levels of radioelectric exposure. In accordance with European directives and the recommendations of health organizations. It establishes maximum field densities for the environment of the emitting antennas.
  • Emission measurement and control protocol.
  • These reference levels will help us to ensure that we do not exceed the exposure to the fields recommended by health organizations.

Maximum tolerable electromagnetic field levels

The reference levels are the maximum field we can have (as an average) to respect the maximum exposure levels. The measurement should be averaged over 6 minutes and is usually done with a broadband probe up to 3 Ghz.

As can be seen, in the frequency band most commonly used in mobile telephony (400-2000Mhz), which is the type of emission that generates most of the conflicts, the highest admissible field density is 27.5 V/m.

This level is met in most of the measurements performed by K2Ingenieros, although there may be special cases in which these levels are exceeded and it is necessary to make additional measurements. It is very prudent to set the alert level at 20 V/m and investigate further if it is exceeded: measure at more points, at other times, etc. otherwise it could incur in illegality and / or in conditions harmful to health.

The usual levels are between 0.5 and 2V/m in city centers or in the vicinity of transmitter towers. The highest values in cities are usually recorded on the rooftops of buildings or in rooms that have a direct line of sight to cell phone transmitter panels. In these cases, it is rare to exceed 10V/m of radiolelectric radiation level.

All measurements performed by K2Ingenieros are made in accordance with these regulations, as well as the Order CTE/23/2002 of January 11, 2002, and the order ITC/749/2010 that modifies it.

 

WaveControl SMP2 Probe for Rental

Call now: 607 36 99 66

 

Renting a meter or contracting radioelectric measurements

Whether it is for a single measure, or to hire several of them contact us. For this purpose you could:

  • Rent a WaveControl SMP2 field meter. low and high frequency probes are available to cover the entire band.
  • Contract multiple measurements: since 2005, we have been performing radioelectric control measurements, following the protocol of RD 1066 of 2001 throughout the national geography.
  • Health and safety studies for companies: We have also carried out studies for multiple companies, which can ensure compliance with the protocol and a report issued by a neutral expert.